<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-13 15-55-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 46 dBuV YLEX
Pilot RDS Phase Difference
7.3 kHz 2.5 kHz 67 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 64 kHz 19008 1,4625
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,4 dBr 3,68 dBr 5,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 15:55, 13.12.2025
RT
"YleX Viikonloppu: Sonny Kylä-Liuhala "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 64 kHz MIN: 12 kHz % above 76 kHz: 1,4625 Acquired: 2025/12/13 15.54.15 Total samples: 19008 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,0 dBr MIN: 1,4 dBr AVE: 3,68 dBr % above 12,2 dBr: 0,0 Last value: 4,4 dBr (2025/12/13 15.54.15) 15.40 15.42 15.44 15.46 15.48 15.50 15.52 15.54 0 2 4 6 Pm [dBr]